LCD Display Overview

Default Display Screens

Overview 0: Status & Time

Normal
T:14:30 D:15-03-
Normal:System operating normally
Increasing:Ramping up inverter power
Limiting:Actively limiting inverter output
Met-com-fail1:Communication failure with meter 1
Met-com-fail2:Communication failure with meter 2
ct-fail:Current transformer failure
OV-G Current:Over-generation current detected
Cont. OV-G-I:Continuous over-generation incident
Fault Reset:System resetting from fault
Time Format:T:HH:MM D:DD-MM-YYYY

Overview 1: Power Flow

Grid:-1500W
Load: 3500W
Grid:Negative = Import from grid, Positive = Export to grid
Load:Current power consumption
Format:Power grid:±XXXXW / Power load:XXXXW

Overview 2: Generation & Control

Inv: 5000W
Control: 85.5%
Inv:Combined output of all connected inverters
Control:Current control level (0.0-100.0%)
Format:Power inv:XXXXW / Ctrl Percent:XX.X

The LCD automatically cycles through these three main screens every 3 seconds, providing key system information at a glance. Screen 0 shows system status and current time, Screen 1 displays power flow information, and Screen 2 shows generation and control parameters.

Main Menu Structure

  • Information

    Real-time measurements and system status

  • Settings

    Basic configuration options

  • Advanced Info

    Detailed system information and diagnostics

  • Advanced Settings

    Advanced configuration and control options